Is your PN16 pipe really PN16? Check the wall

A pipe's pressure rating comes from its wall thickness. Here is how we check irrigation pipe, fittings and pumps before you pay.

Irrigation and farm equipment imported from China

In short: a thinner pipe wall printed with a higher pressure rating looks identical until it bursts in the field. We measure the wall and compare it with the printed rating.

The buyer's question

The pipe is printed PN16. How do you know it will hold 16 bar?

The risk

A plastic pipe's pressure rating depends on the ratio of its outside diameter to its wall thickness (the SDR). For PE100 pipe, SDR11 corresponds to 16 bar. If the wall is thinner than it should be, the printed rating is wrong, and you will only find out under pressure in the field.

What Africa Opal checks

  • The print line: material, SDR, PN, standard and batch number
  • Outside diameter, and minimum wall thickness at eight or more points per sample
  • The measured SDR against the printed PN
  • Cut sections for voids, and square cut ends
  • Pressure and leak tests on fittings
  • Pump nameplates (kW, head, flow, voltage) against the quoted pump curve, with a run test where possible

What you get

Measured values for each sample against your order, with photographs, before the balance is paid.

What this is not: a long-term pressure test or a CBCA Certificate of Conformity.

Africa Opal Africa Opal (Private) Limited Freight, inspection, verification and sourcing · 23 Bessborough Road, Bulawayo · Harare Reg. 68534A01112025 · WhatsApp +263 771 755 585 · enquires@africaopal.co.zw